Single Phase Specifications:

  • 1 KVA, 2 of double wound iron core EI step down transformer .
  • Primary: 230V AC / 1.5A brought out on 2×2 SBSS Socket X 2
  • Secondary: 200VAC /1.5A , brought out on 2×2 SBSS Socket X 2 secondary’s.

Mechanical Specifications:

  • Aluminum rack of 4 x 2 matrix will provide as flat demo panel system to house all experiment
  • Dimension: 940 (H) x 1176(L) x 305 (D)mm.
  • Lightweight sturdy aluminum power coated flat demo panel system containing followings panel will be provided.
    • Input single phase starter panel
    • AC Secondary Voltmeter Panel
    • AC Primary Voltmeter Panel
    • Dual range primary side AC ammeter panel
    • Dual range secondary side DC Ammeter Panel
    • Milliohm (V-I Method)/ Reactive – Capacitive
    • Resistive Load & Dimmer
    • 230/1 Phase Transformer panel
    • 1 Phase MCB isolator Panel
    • Integrated AC (1 Phase)
    • Online Monitoring and Analysis
  • Modbus RS 485 interfacing to measure & Analysis of power and
  • Measurement Panel
  • It should be divided in to various colorful screw less overlay showing circuit diagram to perform the following experiments as under:
    • Finding transformer equivalent circuit, study of transformer load regulation, Back to Back Test (Sumpner Test) on two identical single-phase transformers,
    • Measurement of winding temperature, Effect of type of load on transformer output waveform
    • It should have Test points facilities to observe different
    • Set of patch

Operating manual to be given in hard and soft copy in pen drive with all experiments covered should be provided.

Integrated AC (3/1 phase ) measurement panel

 

Consist of (98x96mm) Digital meter for 3phase & 1 Phase measures Voltage line to line * Line to Neutral, Current for all 3 phase up to 5A.

 

Power factor, frequency , Watt , VAR, VAR, VA and energy in KWHR.

 

Potential Transformer Panel.

 

Voltage Transformer (2Nos.), 1 Standard and 1 under test primary 230V & Secondary 24 VAC

 

Multifunction 1 Phase Meter : Aux Supply: 230VAC

 

50MHz, Voltage : 0 to 300V, Current: 1A/ 5A Range,

 

Display: LCD Display, CTR: 10/1A

 

Modbus RS 485 interfacing to measure & analysis of power and energy.

 

V, I, Hz, Pf, KVA, KW, KWH, etc. with Data Loggings Software online Monitoring and Analysis.

 

Modbus RS 485 interfacing to measure & analysis of power and energy

 

On primary and secondary terminals of PT brought out on front panel for connection.

 

Lamp Load & Resistor (AC Resistors & DC Resistors) Load panel, Inductive and capacitive (LC) Load Panel provided to cover the following experiments:

Current Transformer testing

Potential Transformer Testing

Calibration of single Phase Energy Testing

Measurement of 3 Phase power by 1,2, 3 Wattmeter methods.

Measurement of single phase power 3 ammeter Method.

Measurement of single phase power 3 Voltmeter Method.

Setup for patch cords

Operating manual to be given in hard and soft copy in pen drive with all experiments covered should be provided.

Single Phase Specifications:

  • 1 KVA, 2 of double wound iron core EI step down transformer .
  • Primary: 230V AC / 1.5A brought out on 2×2 SBSS Socket X 2
  • Secondary: 200VAC /1.5A , brought out on 2×2 SBSS Socket X 2 secondary’s.

Mechanical Specifications:

  • Aluminum rack of 4 x 2 matrix will provide as flat demo panel system to house all experiment
  • Dimension: 940 (H) x 1176(L) x 305 (D)mm.
  • Lightweight sturdy aluminum power coated flat demo panel system containing followings panel will be provided.
    • Input single phase starter panel
    • AC Secondary Voltmeter Panel
    • AC Primary Voltmeter Panel
    • Dual range primary side AC ammeter panel
    • Dual range secondary side DC Ammeter Panel
    • Milliohm (V-I Method)/ Reactive – Capacitive
    • Resistive Load & Dimmer
    • 230/1 Phase Transformer panel
    • 1 Phase MCB isolator Panel
    • Integrated AC (1 Phase)
    • Online Monitoring and Analysis
  • Modbus RS 485 interfacing to measure & Analysis of power and
  • Measurement Panel
  • It should be divided in to various colorful screw less overlay showing circuit diagram to perform the following experiments as under:
    • Finding transformer equivalent circuit, study of transformer load regulation, Back to Back Test (Sumpner Test) on two identical single-phase transformers,
    • Measurement of winding temperature, Effect of type of load on transformer output waveform
    • It should have Test points facilities to observe different
    • Set of patch

Operating manual to be given in hard and soft copy in pen drive with all experiments covered should be provided.

Integrated AC (3/1 phase ) measurement panel

Consist of (98x96mm) Digital meter for 3phase & 1 Phase measures Voltage line to line * Line to Neutral, Current for all 3 phase up to 5A.

Power factor, frequency , Watt , VAR, VAR, VA and energy in KWHR.

Potential Transformer Panel.

Voltage Transformer (2Nos.), 1 Standard and 1 under test primary 230V & Secondary 24 VAC

Multifunction 1 Phase Meter : Aux Supply: 230VAC

50MHz, Voltage : 0 to 300V, Current: 1A/ 5A Range,

Display: LCD Display, CTR: 10/1A

Modbus RS 485 interfacing to measure & analysis of power and energy.

V, I, Hz, Pf, KVA, KW, KWH, etc. with Data Loggings Software online Monitoring and Analysis.

Modbus RS 485 interfacing to measure & analysis of power and energy

On primary and secondary terminals of PT brought out on front panel for connection.

Lamp Load & Resistor (AC Resistors & DC Resistors) Load panel, Inductive and capacitive (LC) Load Panel provided to cover the following experiments:

Current Transformer testing

Potential Transformer Testing

Calibration of single Phase Energy Testing

Measurement of 3 Phase power by 1,2, 3 Wattmeter methods.

Measurement of single phase power 3 ammeter Method.

Measurement of single phase power 3 Voltmeter Method.

Setup for patch cords