VOLTAGE/CURRENT/ ENERGY / WATT MEASUREMENT TRAINER Model : MCTPL – 1105

The setup should be designed with following control panels mounted on the table standing ‘Aluminum Rack’ arrangement for essay understanding & performing various experiments for easy understanding & performing various experiments Input 3 Phase DOL Starter Panel Provided.

4 Pole MCB of 415 V/1A .

DOL 9A Contactor with 230V/ 50 Hz / 11VA COIL.

Bimetallic thermal O/L relay with range 1.4A-2.3A.

Integrated AC (3/1 Phase ) Measurement Panel.

Consist of 2 Nos. of (48x96mm) Digital meters one each for 3Phase & 1Phase Measure V, I, PF (0.2lag unity – 0.2 lead) , Hz

Current for 3ɸ meter = 1.5A (Balanced Load)

1A/5A for 1ɸ meter (170-250V)

1 Phase motor, alternator & synchronous motor panel

1 Phase MCBs of 4A /1.6A – 2 Nos.

Integrated AC (3/1 phase ) measurement panel

Consist of (98x96mm) Digital meter for 3phase & 1 Phase measures Voltage line to line * Line to Neutral, Current for all 3 phase up to 5A.

Power factor, frequency , Watt , VAR, VAR, VA and energy in KWHR.

Potential Transformer Panel.

Voltage Transformer (2Nos.), 1 Standard and 1 under test primary 230V & Secondary 24 VAC

Multifunction 1 Phase Meter : Aux Supply: 230VAC

50MHz, Voltage : 0 to 300V, Current: 1A/ 5A Range,

Display: LCD Display, CTR: 10/1A

Modbus RS 485 interfacing to measure & analysis of power and energy.

V, I, Hz, Pf, KVA, KW, KWH, etc. with Data Loggings Software online Monitoring and Analysis.

Modbus RS 485 interfacing to measure & analysis of power and energy

On primary and secondary terminals of PT brought out on front panel for connection.

Lamp Load & Resistor (AC Resistors & DC Resistors) Load panel, Inductive and capacitive (LC) Load Panel provided to cover the following experiments:

Current Transformer testing

Potential Transformer Testing

Calibration of single Phase Energy Testing

Measurement of 3 Phase power by 1,2, 3 Wattmeter methods.

Measurement of single phase power 3 ammeter Method.

Measurement of single phase power 3 Voltmeter Method.

Setup for patch cords

Operating manual to be given in hard and soft copy in pen drive with all experiments covered should be provided.

The setup should be designed with following control panels mounted on the table standing ‘Aluminum Rack’ arrangement for essay understanding & performing various experiments for easy understanding & performing various experiments Input 3 Phase DOL Starter Panel Provided.

4 Pole MCB of 415 V/1A .

 

DOL 9A Contactor with 230V/ 50 Hz / 11VA COIL.

 

Bimetallic thermal O/L relay with range 1.4A-2.3A.

 

Integrated AC (3/1 Phase ) Measurement Panel.

 

Consist of 2 Nos. of (48x96mm) Digital meters one each for 3Phase & 1Phase Measure V, I, PF (0.2lag unity – 0.2 lead) , Hz

 

Current for 3ɸ meter = 1.5A (Balanced Load)

 

1A/5A for 1ɸ meter (170-250V)

 

1 Phase motor, alternator & synchronous motor panel

 

1 Phase MCBs of 4A /1.6A – 2 Nos.

Integrated AC (3/1 phase ) measurement panel

 

Consist of (98x96mm) Digital meter for 3phase & 1 Phase measures Voltage line to line * Line to Neutral, Current for all 3 phase up to 5A.

 

Power factor, frequency , Watt , VAR, VAR, VA and energy in KWHR.

 

Potential Transformer Panel.

 

Voltage Transformer (2Nos.), 1 Standard and 1 under test primary 230V & Secondary 24 VAC

 

Multifunction 1 Phase Meter : Aux Supply: 230VAC

 

50MHz, Voltage : 0 to 300V, Current: 1A/ 5A Range,

 

Display: LCD Display, CTR: 10/1A

 

Modbus RS 485 interfacing to measure & analysis of power and energy.

 

V, I, Hz, Pf, KVA, KW, KWH, etc. with Data Loggings Software online Monitoring and Analysis.

 

Modbus RS 485 interfacing to measure & analysis of power and energy

 

On primary and secondary terminals of PT brought out on front panel for connection.

 

Lamp Load & Resistor (AC Resistors & DC Resistors) Load panel, Inductive and capacitive (LC) Load Panel provided to cover the following experiments:

Current Transformer testing

Potential Transformer Testing

Calibration of single Phase Energy Testing

Measurement of 3 Phase power by 1,2, 3 Wattmeter methods.

Measurement of single phase power 3 ammeter Method.

Measurement of single phase power 3 Voltmeter Method.

Setup for patch cords

Operating manual to be given in hard and soft copy in pen drive with all experiments covered should be provided.