Ash Content Apparatus

Ash-Content-Apparatus

Make: Metlor

Model: SL-FT-022

Standard: ASTM D2584, ASTM D5630, ISO 3451

Scope: An Ash test is used to determine if a material is filled. The test will identify the total filler content. It cannot identify individual percentages in multi-filled materials without additional test procedures being performed. An ash test cannot be used to determine the percent carbon fiber or percent carbon black since carbon burns off during the Ash test.

Procedure: An Ash test involves taking a known amount of sample, placing the weighed sample into a dried / pre-weighed porcelain crucible, burning away the polymer in an air atmosphere at temperatures above 500°C, and weighing the crucible after it is has been cooled to room temperature in a desiccator. Ash residue remaining in the crucible is considered filler unless the residue is less than 1%. Residues of less than 1% are typically the result of additives that did not burn off.

Data: The Ash test result is expressed as % ash. A magnified optical examination of the ash residue is performed to determine if the ash is glass, mineral, or a combination of both. The total ash content equals the weight of the ash divided by the weight of the original sample multiplied by 100%.

Make: Metlor
Model: SL-FT-022
Standard: ASTM D2584, ASTM D5630, ISO 3451
Scope: An Ash test is used to determine if a material is filled. The test will identify the total filler content. It cannot identify individual percentages in multi-filled materials without additional test procedures being performed. An ash test cannot be used to determine the percent carbon fiber or percent carbon black since carbon burns off during the Ash test.
Procedure: An Ash test involves taking a known amount of sample, placing the weighed sample into a dried / pre-weighed porcelain crucible, burning away the polymer in an air atmosphere at temperatures above 500°C, and weighing the crucible after it is has been cooled to room temperature in a desiccator. Ash residue remaining in the crucible is considered filler unless the residue is less than 1%. Residues of less than 1% are typically the result of additives that did not burn off.
Data: The Ash test result is expressed as % ash. A magnified optical examination of the ash residue is performed to determine if the ash is glass, mineral, or a combination of both. The total ash content equals the weight of the ash divided by the weight of the original sample multiplied by 100%.
Specifications:
Internal Chamber Size For K-MF-01
Width 10cm x Height 10cm x Depth 22.5cm
System Status
Digital
Temperature Controller
Micro processor based double display digital PID controller
Heating
Through custom high grade nichrome wire
Temperature Range
Ambient to 950°C
Temperature Accuracy
±5°C or better
Timer
Micro processor based double display digital timer at optional
Timer Range
Up to 999.9 Seconds / Minutes
Safety MCB / Fuse
Fuse available on electric panel
Insulation
100mm double wall thick cera-wool insulation
Mat. Of Construction
Inner chamber: Tough treated ceramic
Outer chamber: Heavy CRC dual side powder coated
Power Supply
230V AC, Single phase, 50Hz Specifications:
Internal Chamber Size For K-MF-01Width 10cm x Height 10cm x Depth 22.5cm
System StatusDigital
Temperature ControllerMicro processor based double display digital PID controller
HeatingThrough custom high grade nichrome wire
Temperature RangeAmbient to 950°C
Temperature Accuracy±5°C or better
TimerMicro processor based double display digital timer at optional
Timer RangeUp to 999.9 Seconds / Minutes
Safety MCB / FuseFuse available on electric panel
Insulation100mm double wall thick cera-wool insulation
Mat. Of ConstructionInner chamber: Tough treated ceramic
Outer chamber: Heavy CRC dual side powder coated
Power Supply230V AC, Single phase, 50Hz